{"product_id":"38auq-gemini®-commercial-split-system-heat-pump","title":"38AUQ Gemini® Commercial Split System Heat Pump","description":"\u003ch2\u003eCommercial Split System Heat Pump\u003cbr\u003ewith Puron® Refrigerant\u003c\/h2\u003e\n\u003ch3\u003e6 TO 20 NOMINAL TONS\u003c\/h3\u003e\n\u003cp class=\"product-text\"\u003eThe Gemini® 38AU series outdoor units and matched with the 40RU series indoor air handlers offer a wide variety of options for your HVAC application needs. This series is designed for long dependable operation whether it's a rooftop or on-the-ground installation. All GEMINI 38AU Condensing Units and 40RU Fan Coils use environmentally sound Puron® refrigerant. Together, they create a reliable split system that provides easy solutions to a wide range of commercial HVAC needs.\u003c\/p\u003e\n\u003ch3\u003ePERFORMANCE FEATURES\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e38AUQ Heat Pump EERs up to 11.0 and 3.5 COP\u003c\/li\u003e\n\u003cli\u003eASHRAE 90.1 Efficiency Compliant\u003c\/li\u003e\n\u003cli\u003eStandard crankcase heater\u003c\/li\u003e\n\u003cli\u003eCompressor vibration isolation\u003c\/li\u003e\n\u003cli\u003eLow ambient temperature control\u003c\/li\u003e\n\u003cli\u003eUnit performance certified in accordance with ARI standard 340\/360\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRELIABILITY FEATURES\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh and low-pressure switches\u003c\/li\u003e\n\u003cli\u003eAnti-short cycling protection\u003c\/li\u003e\n\u003cli\u003ePrepainted, galvanized steel cabinets that passes 500-hour salt-spray test\u003c\/li\u003e\n\u003cli\u003eCompressor overload protection\u003c\/li\u003e\n\u003cli\u003eScroll compressor\u003c\/li\u003e\n\u003cli\u003eE-Coat coil protection\u003c\/li\u003e\n\u003cli\u003eUL, UL, Canada or ETL approved\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eINSTALLATION FEATURES\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eShipped with Puron (R-410A) refrigerant partial charge\u003c\/li\u003e\n\u003cli\u003eSingle-piece design\u003c\/li\u003e\n\u003cli\u003ePerimeter base rail with forklift slots and lifting holes facilitates rigging\u003c\/li\u003e\n\u003cli\u003eSuitable for mounting on the ground or the rooftop\u003c\/li\u003e\n\u003cli\u003e24V control circuit transformer permits quick, easy wiring of thermostats\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMAINTENANCE FEATURES\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eComfort Alert™ diagnostic board\u003c\/li\u003e\n\u003cli\u003ePowered and non-powered 115-v convenience outlet\u003c\/li\u003e\n\u003cli\u003eCompressor access panel with easy grip handle\u003c\/li\u003e\n\u003cli\u003eEasy starting, no-strip screw feature\u003c\/li\u003e\n\u003cli\u003eNon-fused disconnect switch\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSTANDARD LIMITED WARRANTY\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e5 years parts only on compressor\u003c\/li\u003e\n\u003cli\u003eOne year parts only on all other parts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e38AUQ\/40RUQ AHRI COOLING RATINGS\u003c\/h3\u003e\n\u003cdiv id=\"specifications\"\u003e\n\u003ctable data-role=\"table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eUnit\u003c\/th\u003e\n\u003cth\u003eCooling Stages\u003c\/th\u003e\n\u003cth\u003eNominal Capacity (Tons)\u003c\/th\u003e\n\u003cth\u003eNet Cooling Capacity (MBH)\u003c\/th\u003e\n\u003cth\u003eTotal Power (kW)\u003c\/th\u003e\n\u003cth\u003eEER\u003c\/th\u003e\n\u003cth\u003eIEER\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e38AUQ07 \/ 40RUQ07\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003e70.0\u003c\/td\u003e\n\u003ctd\u003e6.4\u003c\/td\u003e\n\u003ctd\u003e11.0\u003c\/td\u003e\n\u003ctd\u003e12.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e38AUQ08 \/ 40RUQ08\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e7.5\u003c\/td\u003e\n\u003ctd\u003e89.0\u003c\/td\u003e\n\u003ctd\u003e8.1\u003c\/td\u003e\n\u003ctd\u003e11.0\u003c\/td\u003e\n\u003ctd\u003e12.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e38AUQ12 \/ 40RUQ12\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e112.0\u003c\/td\u003e\n\u003ctd\u003e10.2\u003c\/td\u003e\n\u003ctd\u003e11.0\u003c\/td\u003e\n\u003ctd\u003e12.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e38AUQ16 \/ 40RUQ16\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003e178.0\u003c\/td\u003e\n\u003ctd\u003e16.8\u003c\/td\u003e\n\u003ctd\u003e10.6\u003c\/td\u003e\n\u003ctd\u003e11.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e38AUQ25 \/ 40RUQ25\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e220.0\u003c\/td\u003e\n\u003ctd\u003e20.8\u003c\/td\u003e\n\u003ctd\u003e10.7\u003c\/td\u003e\n\u003ctd\u003e11.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3\u003e38AUQ\/40RUQ AHRI HIGH HEAT RATINGS AT 47°F (8°C)\u003c\/h3\u003e\n\u003cdiv id=\"specifications\"\u003e\n\u003ctable data-role=\"table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eUnit\u003c\/th\u003e\n\u003cth\u003eHeating Stages\u003c\/th\u003e\n\u003cth\u003eNominal Capacity (Tons)\u003c\/th\u003e\n\u003cth\u003eNet Cooling Capacity (MBH)\u003c\/th\u003e\n\u003cth\u003eTotal Power (kW)\u003c\/th\u003e\n\u003cth\u003eCOP\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e38AUQ07 \/ 40RUQ07\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003e66.0\u003c\/td\u003e\n\u003ctd\u003e5.9\u003c\/td\u003e\n\u003ctd\u003e3.30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e38AUQ08 \/ 40RUQ08\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e7.5\u003c\/td\u003e\n\u003ctd\u003e87.0\u003c\/td\u003e\n\u003ctd\u003e7.7\u003c\/td\u003e\n\u003ctd\u003e3.30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e38AUQ12 \/ 40RUQ12\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e106.0\u003c\/td\u003e\n\u003ctd\u003e9.4\u003c\/td\u003e\n\u003ctd\u003e3.30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e38AUQ16 \/ 40RUQ16\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003e178.0\u003c\/td\u003e\n\u003ctd\u003e15.3\u003c\/td\u003e\n\u003ctd\u003e3.40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e38AUQ25 \/ 40RUQ25\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e214.0\u003c\/td\u003e\n\u003ctd\u003e17.9\u003c\/td\u003e\n\u003ctd\u003e3.50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3\u003e38AUQ\/40RUQ AHRI LOW HEAT RATINGS AT 17°F (-8°C)\u003c\/h3\u003e\n\u003cdiv id=\"specifications\"\u003e\n\u003ctable data-role=\"table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eUnit\u003c\/th\u003e\n\u003cth\u003eHeating Stages\u003c\/th\u003e\n\u003cth\u003eNominal Capacity (Tons)\u003c\/th\u003e\n\u003cth\u003eNet Cooling Capacity (MBH)\u003c\/th\u003e\n\u003cth\u003eTotal Power (kW)\u003c\/th\u003e\n\u003cth\u003eCOP\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e38AUQ07 \/ 40RUQ07\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003e39.0\u003c\/td\u003e\n\u003ctd\u003e5.2\u003c\/td\u003e\n\u003ctd\u003e2.20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e38AUQ08 \/ 40RUQ08\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e7.5\u003c\/td\u003e\n\u003ctd\u003e52.0\u003c\/td\u003e\n\u003ctd\u003e6.9\u003c\/td\u003e\n\u003ctd\u003e2.20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e38AUQ12 \/ 40RUQ12\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e70.0\u003c\/td\u003e\n\u003ctd\u003e9.3\u003c\/td\u003e\n\u003ctd\u003e2.20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e38AUQ16 \/ 40RUQ16\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003e108.0\u003c\/td\u003e\n\u003ctd\u003e13.2\u003c\/td\u003e\n\u003ctd\u003e2.40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e38AUQ25 \/ 40RUQ25\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e130.0\u003c\/td\u003e\n\u003ctd\u003e15.9\u003c\/td\u003e\n\u003ctd\u003e2.40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp class=\"product-text\"\u003e\u003csmall\u003e\u003cstrong\u003eLEGEND\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eAHRI\u003c\/strong\u003e = Air-Conditioning, Heating and Refrigeration Institute\u003cbr\u003e\u003cstrong\u003eASHRAE\u003c\/strong\u003e = American Society of Heating, Refrigerating and Air Conditioning, Inc.\u003cbr\u003e\u003cstrong\u003eEER\u003c\/strong\u003e = Energy Efficiency Ratio\u003cbr\u003e\u003cstrong\u003eIEER\u003c\/strong\u003e = Integrated Energy Efficiency Ratio\u003cbr\u003e\u003cstrong\u003eCOP\u003c\/strong\u003e = Coefficient of Performance\u003c\/small\u003e\u003c\/p\u003e\n\u003cp class=\"product-text\"\u003e\u003csmall\u003e\u003cstrong\u003eNOTES\u003c\/strong\u003e\u003cbr\u003e1. Rated in accordance with ARI Standard 340\/360---07, as appropriate.\u003cbr\u003e2. Ratings are based on:\u003cbr\u003e- Cooling Standard: 27°C (80°F) db, 19°C (67°F) wb indoor air temp and 35°C (95°F) db outdoor air temp.\u003cbr\u003e- IEER Standard: 27°C (80°F) db, 19°C (67°F) wb indoor air temp and 4 various outdoor temperatures.\u003cbr\u003e3. All units comply with ASHRAE 90.1 Energy Standard for minimum EER and IEER requirements.\u003c\/small\u003e\u003c\/p\u003e\n\u003ch3\u003eFACTORY-INSTALLED OPTIONS\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNon-fused Disconnect\u003c\/li\u003e\n\u003cli\u003ePremium, E-coated condenser coil\u003c\/li\u003e\n\u003cli\u003eConvenience outlet (powered)\u003c\/li\u003e\n\u003cli\u003eLow ambient temperature Motormaster® control\u003c\/li\u003e\n\u003cli\u003eLouvered hail guards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFIELD-INSTALLED ACCESSORIES\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLow ambient temperature Motormaster® control\u003c\/li\u003e\n\u003cli\u003eLouvered hail guard\u003c\/li\u003e\n\u003cli\u003eProgrammable thermostats\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Carrier","offers":[{"title":"Default Title","offer_id":43311849308297,"sku":"Item # 4122116 | Model # 38AUQ","price":0.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0566\/9054\/0681\/files\/image_eebedb9f-2980-43e3-86e5-512bef7c3e49.jpg?v=1749090761","url":"https:\/\/www.sabersales.shop\/de-de\/products\/38auq-gemini%c2%ae-commercial-split-system-heat-pump","provider":"Saber Sales","version":"1.0","type":"link"}